Configuration, Code table – Lenze EVS9332xS User Manual

Page 266

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−25

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0594 MONIT SD6

®

0
2
3

Trip
Warning
Off

SD6monitoring
Configuration of "motor temperature sensor"
monitoring

à

Depending on C0086

C0595 MONIT CE4

3

0
2
3

Trip
Warning
Off

CE4monitoring
Configuration of "CAN bus off" monitoring

C0596 NMAX LIMIT

5500 0

{1 rpm}

16000 System speed monitoring

C0597 MONIT LP1

3

0
2
3

Trip
Warning
Off

LP1monitoring
Configuration of motor phase failure
monitoring

C0598 MONIT SD5

3

0
2
3

Trip
Warning
Off

SD5monitoring
Configuration monitoring master current at
X5/1.2 < 2mA

C0599 LIMIT LP 1

5.0

1.0

{0.1 %}

10.0 LP1monitoring

Current limit value for motor phase
monitoring

C0600 FUNCTION

1

0
1
2
3
4
5

OUT = IN1
OUT = IN1 + IN2
OUT = IN1 − IN2
OUT = IN1 × IN2
OUT = IN1 / IN2
OUT = IN1/(100% − IN2)

ARIT2
Function selection

C0601

s

IN

® Selection list 1 ARIT2

Configuration − analog input signals

1

1000 FIXED0%

ARIT2−IN1

2

1000 FIXED0%

ARIT2−IN2

C0602

g −199.99

{0.01 %}

199.99 ARIT2

Display of analog input signals

1 (C0601/1)

2 (C0601/2)

C0606 MONIT OC8

2

0
2
3

Trip
Warning
Off

Configuration of the I

2

× t advance warning

The threshold is set in C0127.

C0610

s

IN

® Selection list

1

ADD
Configuration − analog input signals

1

1000 FIXED0%

ADD1−IN1

2

1000 FIXED0%

ADD1−IN2

3

1000 FIXED0%

ADD1−IN3

C0611

g −199.99

{0.01 %}

199.99 ADD

Display of analog input signals

1 (C0610/1)

2 (C0610/2)

3 (C0610/3)

C0620 DB1 GAIN

1.00

−10.00

{0.01}

10.00 DB1 gain

Gain of dead band component DB1

C0621 DB1 VALUE

1.00

0.00

{0.01 %}

100.00 DB1 dead band

Dead band of DB1

C0622

s

DB1−IN

1000 FIXED0%

® Selection list 1 DB1

Configuration of analog input signal

C0623 (C0622)

g −199.99

{0.01 %}

199.99 DB1

Display of analog input signal

C0630 MAX LIMIT

100.0

0

−199.99

{0.01 %}

199.99 LIM upper limit

Upper limit of limiter LIM1

C0631 MIN LIMIT

−100.0 −199.99

{0.01 %}

199.99 LIM lower limit

Lower limit of limiter LIM1

Advertising