Configuration, Code table – Lenze EVS9332xS User Manual

Page 243

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−2

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0005

s

SIGNAL CFG

1000

Signal configuration
(predefined basic configurations)

0

COMMON

Modified basic configuration

1
2
11

86xx −1−
86xx −2−
86xx −11−

Compatible to 86xx frequency inverter

20
21

922x −20−
922x −21−

Compatible to 922xx frequency inverter

C0005

s

SIGNAL CFG

1000 100

empty

All internal links are deleted

1000

Speed control

The first digit indicates the predefined basic
function, e. g.:

l

1xxx: Speed control

l

4xxx: Torque control with speed limitation

The second digit indicates additional
functions
x0xx: No additional function
x1xx: Brake control
x9xx: In the case of quick stop, the complete
drive system is brought to zero speed in a
phase−controlled manner

The third digit indicates the predefined
voltage source for the control terminals:

l

xx0x: External supply voltage

l

xx1x: Internal supply voltage

The fourth digit indicates the predefined
device control:

l

xxx0: Terminal control

l

xxx1: RS232, RS485 or optical fibre

l

xxx3: INTERBUS or PROFIBUS−DP

l

xxx5: System bus (CAN)

4000

Torque control with speed limitation

5000

Master for digital frequency coupling

6000

Slave to digital frequency bus

7000

Slave to digital frequency cascade

C0006

s

OP MODE

à

Motor control operation

1

SSC norm Y sensorless star standard
motor

à

Depending on C0086

l

Change of C0086 resets value to the
assigned default setting

l

Change of C0006 sets C0086 = 0!

2

Servo async. Y asynchronous motor,
star

3

Servo PM−SM Y PM synchronous motor,
star

11

SSC standard motor sensorless
standard motor, delta

22

Servo asyn asychronous motor, delta

C0009 LECOM

ADDRESS

1

1

{1}

99 LECOM device address

Bus device number when operated via
interface

l

10, 20, ..., 90 reserved for broadcast to
device groups for RS232, RS485, fibre
optics.

C0011 NMAX

3000 500

{1 rpm}

16000 Max speed N

max

Reference value for the absolute and relative
setpoint selection for the acceleration and
deceleration times.

l

Parameter setting via interface:
– Greater changes in one step should only