Step

Key
sequence

Action

1.

Connect the keypad to
standard device 2

2.

Inhibit controller

Terminal X5/28 = LOW
The "IMP" status display is it.
The drive coasts

3.

Pull the plugs X5 and X6

All control terminals have the defined
"LOW" status.

4.

Select C0002 in the
"Load/Store" menu

z y Z Y

Select code C0002 "PAR LOAD" in the
"Load/Store" menu using the arrow keys.

5.

Change to the parameter level

V

The active parameter set is shown, e. g.
display "0" and "Load Default"

6.

Select the correct copy
function

The settings saved in the standard device
are overwritten.

l

Copy all parameter sets available into the
EEPROM of the standard device and save
them permanently.

l

The parameter set that was active
before copying is overwritten.

l

The parameters are not yet active after
copying. Select parameter set and load
it in the main memory.

^ 7.2−7

z

Set "20" "ext −> EEPROM"

l

Copy individual parameter sets into the
main memory of the standard device.

z

Copy parameter set 1 into the main
memory:
Set

ð "11" "Load ext PS1"

Copy parameter set 2 into the main
memory:
Set

ð "12" "Load ext PS2"

Copy parameter set 3 into the main
memory:
Set

ð "13" "Load ext PS3"

Copy parameter set 4 into the main
memory:
Set

ð "14" "Load ext PS4"

7.

Start copying

T V

The "RDY" status display goes off. As
parameter value "BUSY" is displayed.
If "BUSY" goes off, the parameter sets
selected were copied into the standard
device. The "RDY" status display is lit.

8.

Change to the code level

A

V

Display of the operating level

B

V

Display C0002 and "PAR LOAD"

9.

l

If the function "Copy all
parameter sets into the
EEPROM" (C0002 = 20) is
selected, they might have
to be loaded in the main
memory manually.

l

If the function "Copy
individual parameter sets
into the main memory"
(C0002 = 1x) is selected,
they might have to be
saved permanently in the
EEPROM manually.

z y Z Y

Select code C0003 "PAR SAVE" in the
"Load/Store" menu using the arrow keys
and store the contents of the main
memory permanently.

10. Plug in plugs X5 and X6

11. Enable controller

Terminal X5/28 = HIGH