Configuration, Code table – Lenze EVS9332xS User Manual

Page 253

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−12

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0206 PROD. DATE

g

Production date

C0207 DL INFO 1

g

Download−Info 1

C0208 DL INFO 2

g

Download info 2

C0209 DL INFO 3

g

Download info 3

C0220 NSET TIR ADD

0.000 0.000

{0.001 s}

999.900 NSET

Acceleration time T

ir

of the additional

setpoint for NSET
(based on speed variation 0...n

max.

)

C0221 NSET TIF ADD

0.000 0.000

{0.001 s}

999.900 NSET

Deceleration time T

if

of the additional

setpoint for NSET
(based on speed variation 0...n

max.

)

C0222 PCTRL VP

1.0

0.1

{0.1}

500.0 PCTRL

V

p

gain

C0223 PCTRL TN

400

20

{1 ms}

99999 PCTRL

T

n

I component

99999 ms: Switched off

C0224 PCTRL KD

0.0

0.0

{0.1}

5.0 PCTRL

K

d

differential component

C0241 CMP RFG−I = O

1.00

0.00

{0.01 %}

100.00 NSET

Threshold ramp function generator for main
setpoint Input = output, (100 % = n

max

)

C0244 BRK M SET

0

−100

{1 %}

100 BRK1

Holding torque of the DC injection brake
100 % = value of C0057

C0250 FCODE 1BIT

0

0
1

Lower limit
Upper limit

FCODE 1 bit digital

C0252 ANGLE OFFSET

0

−245760000

{1 inc}

245760000 DFSET

Anglular offset, fixed angular offset for
digital frequency configurations

l

1 rev. = 65536 inc

C0253 ANGLE N−TRIM

®

−32767

{1 inc}

32767 DFSET

Speed−dependent phase trimming

à

Depending on C0005, C0025, C0490

l

Change of C0005, C0025, or C0490 resets
C0253 to the Lenze settingassigned

l

1 rev. = 65536 inc

l

C0253 is reached at 15000 rpm

C0254 VP ANGLE CTRL

0.400

0

0.0000

{0.0001}

3.9999 MCTRL

V

p

angle controller

C0255 THRESHOLD

P03

32768

0

10

{1 inc}

1800000000 Following error limit P03

l

1 rev. = 65536 inc

l

Following error > C0255 triggers fault
"P03"

C0260 MPOT1 HIGH

100.0

0

−199.99

{0.01 %}

199.99 MPOT1

Upper limit (condition: C0260 > C0261)

C0261 MPOT1 LOW

−100.0 −199.99

{0.01 %}

199.99 MPOT1

Lower limit (condition: C0261 < C0260)

C0262 MPOT1 TIR

10.0

0.1

{0.1 s}

6000.0 MPOT1

Acceleration time
(relating to change 0...100 %)

C0263 MPOT1 TIF

10.0

0.1

{0.1 s}

6000.0 MPOT1

Deceleration time
(based on change 0...100 %)

Advertising