Commissioning

Basic settings

Motor temperature monitoring with KTY

6

6.5

6.5.6

l

6.5−17

EDSVS9332S EN 6.0−07/2013

The temperature and resistance range can be adapted to the KTY used.

ƒ C1190 = 0: Fixed operating range for KTY in Lenze motors (Lenze

setting)

ƒ C1190 = 1: Adjustable operating range

T [ ° C ]

R [ O h m ]

R 2

( C 1 1 9 2 / 2 )

T 1

( C 1 1 9 1 / 1 )

R 1

( C 1 1 9 2 / 1 )

T 2

( C 1 1 9 1 / 2 )

a

Fig. 6.5−8

Setting of the operating range for the KTY (C1190 = 1)

The operating range is specified by means of limit values and is in the almost
linear section of the graph (a). The operating values are determined by
interpolation.
C1191/1
C1191/2

Setting of the lower and upper temperature value (T1, T2)
corresponding to the KTY used.

C1192/1
C1192/2

Setting of the lower and upper resistance value corresponding to
the KTY used.

Adjustment of KTY operating
range