Configuration

Code table

8

8.4

l

8.4−41

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0941 DENOMINATO

R

1

1

{1}

32767 CONV1

Denominator

C0942

s

CONV1−IN

1000 FIXED0%

® Selection list 1 CONV1

Configuration of analog input

C0943 (C0942)

g −199.99

{0.01 %}

199.99 CONV1

Display of analog input signal

C0945 NUMERATOR

1

−32767

{1}

32767 CONV2

Numerator

C0946 DENOMINATO

R

1

1

{1}

32767 CONV2

Denominator

C0947

s

IN

1000 FIXED0%

® Selection list 1 CONV2

Configuration of analog input

C0948 (C0947)

g −199.99

{0.01 %}

199.99 CONV2

Display of analog input signal

C0950 NUMERATOR

1

−32767

{1}

32767 CONV3

Numerator

C0951 DENOMINATO

R

1

1

{1}

32767 CONV3

Denominator

C0952

s

IN

1000 FIXEDPHI−0

® Selection list 4 CONV3

Configuration of analog input

C0953 (C0952)

g −32767

{1 rpm}

32767 CONV3

Display of analog input signal

C0955 NUMERATOR

1

−32767

{1}

32767 CONV4

Numerator

C0956 DENOMINATO

R

1

1

{1}

32767 CONV4

Denominator

C0957

s

IN

1000 FIXEDPHI−0

® Selection list 4 CONV4

Configuration of analog input

C0958 (C0957)

g −32767

{1 rpm}

32767 CONV4

Display of analog input signal

C0960 FUNCTION

1

1
2
3

Characteristic 1
Characteristic 2
Characteristic 3

CURVE
Selection of the characteristic function

C0961 Y0

0.00

0.00

{0.01 %}

199.99 CURVE

Configuration of grid point

C0962 Y1

50.00 0.00

{0.01 %}

199.99 CURVE

Configuration of grid point

C0963 Y2

75.00 0.00

{0.01 %}

199.99 CURVE

Configuration of grid point

C0964 Y100

100.0

0

0.00

{0.01 %}

199.99 CURVE

Configuration of grid point

C0965 X1

50.00 0.01

{0.01 %}

99.00 CURVE

Configuration of grid point

C0966 X2

75.00 0.01

{0.01 %}

99.00 CURVE

Configuration of grid point

C0967

s

IN

1000 FIXED0%

® Selection list 1 CURVE

Configuration of analog input

C0968 (C0967)

g −199.99

{0.01 %}

199.99 CURVE

Display of analog input signal

C0970

s

N−SET

1000 FIXED0%

® Selection list 1 MFAIL

Configuration of speed input signal (setpoint
path)

C0971

s

FAULT

1000 FIXED0

® Selection list 2 MFAIL

Configuration of digital input signal
(activation of the mains failure control)