Overcurrent operation, Technical data – Lenze EVS9332xS User Manual

Page 45

Advertising
background image

Technical data

Rated data
Overcurrent operation

3

3.3
3.3.3

l

3.3−4

EDSVS9332S EN 6.0−07/2013

3.3.3

Overcurrent operation

Under the operating conditions described here, the
EVS9321−xS ... EVS9324−xS controllers can supply a rated output current
which is up to twice as high.

)

Note!

If you enter values > 1.5 × rated output current under C0022, the
controller switches to overcurrent operation.

ƒ

Switching between overcurrent operation and standard
operation is only possible if the controller is inhibited
(X5/28 = LOW).

ƒ

The continuous current is automatically reduced to 70 % of
the rated output current.

3.3.3.1

Operation at 400 V

Basis of the data

Voltage

Frequency

AC mains connection

[V

rate

d

]

3/PE AC 320 V − 0 % ... 440 V + 0 %

45 Hz − 0 % ... 65 Hz + 0 %

DC−mains connection
(alternatively)

[U

DC

]

DC 450 V − 0 % ... 620 V + 0 %

˘

Output voltage

With mains choke

3 ~ 0 approx. 94 % V

rated

˘

Without mains choke

3 ~ 0 ... U

N

˘

9300

Mains current

1)

Typical motor power

Output power

Power loss

With

mains choke

Without

mains choke

ASM

(4−pole)

8 kHz

2)

U, V, W

+U

G

, −U

G

3)

Type

I

r

[A]

I

r

[A]

P

r

[kW]

P

r

[hp]

S

r8

[kVA]

P

DC

[kW]

P

V

[W]

EVS9321−xS

1.5

2.1

0.37

0.5

1.0

2.0

100

EVS9322−xS

2.5

3.5

0.75

1.0

1.7

0.75

110

EVS9323−xS

3.9

5.5

1.5

2.0

2.7

2.2

140

EVS9324−xS

7.0

˘

3.0

4.0

4.8

0.75

200

Bold print = Lenze setting

1)

Mains currents at 8 kHz switching frequency

2)

Switching frequency of the inverter

3)

Power which can additionally be drawn from the DC bus at operation with power−adapted motor

Advertising
This manual is related to the following products: