Configuration – Lenze EVS9332xS User Manual

Page 288

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−47

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C1190

0

Temperature characteristic for PTC
thermistors
Selection of the characteristic for PTC
thermistors at X7 or X8 for detecting the
motor temperature

0

Standard

Characteristic for PTC thermistors in Lenze
motors

1

Characteristic

Characteristic for application−specific PTC
thermistors

C1191

0

{1 °C}

255 Temperature range for PTC thermistors

Define temperature points on the
characteristic for PTC thermistors

1

100

Lower temperature T1

2

150

Upper temperature T2

C1192

0

{1

W}

3000 Resistance range for PTC thermistors

Define resistance points on the characteristic
for PTC thermistors

1

1670

Resistance R1 at T1

2

2225

Resistance R2 at T2

C1195

s

OUT.D2

1000

FIXED0INC

® Selection list 3 AIF−OUT

Configuration of angle input signal

C1196 (C1195)

g −2147483647

{1}

2147483647 AIF−OUT

Input signal display

C1197 IN.D2

g

AIF−IN
Input signal display

C1200

s

® Selection list 3 PHADD1

Configuration − phase input signals

1 IN1

1000 FIXED0INC

2 IN2

1000 FIXED0INC

3 IN3

1000 FIXED0INC

C1201

g −2147483647

{1}

2147483647 PHADD1

Display of input signals

1 IN1

2 IN2

3 IN3

C1205

s

® Selection list 3 PHCMP2

Input signal configuration

1 IN1

1000 FIXED0INC

2 IN2

1000 FIXED0INC

C1206

g −2147483647

{1}

2147483647 PHCMP2

Display of input signals

1 IN1

2 IN2

C1207 FUNCTION

2

1
2

IN1 < IN2
|IN1| < |IN2|

PHCMP2
Selection of the comparison operation

C1210

s

® Selection list 2 STORE1

Configuration of digital input signals

1 STORE1−RESET

1000 FIXED0

2 STORE1−ENTP

1000 FIXED0

3 STORE1−ENWI

N

1000 FIXED0

4 STORE1−LOAD0

1000 FIXED0

5 STORE1−LOAD1

1000 FIXED0

Advertising