Configuration – Lenze EVS9332xS User Manual

Page 270

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−29

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0731 OSZ STATUS

0

0
1
2
3
4
5

Measurement completed
Measurement active
Trigger detected
Abort
Abort after trigger
Read memory

OSZ
Current operating status

C0732

s

® Selection list 1 OSZ

Configuration − analog input signals

1 CHANNEL1

1000 FIXED0%

2 CHANNEL2

1000 FIXED0%

3 CHANNEL3

1000 FIXED0%

4 CHANNEL4

1000 FIXED0%

C0733

® Selection list 2 OSZ

Trigger input

1 TRIG INP

1000 FIXED0

C0734 TRIG−SOURCE

1

0
1
2
3
4

Digital trigger input
Measuring channel 1
Measuring channel 2
Measuring channel 3
Measuring channel 4

OSZ
Selection of trigger source

C0735 TRIGGER−LEVEL

0

−32767

{1}

32767 OSZ

Set trigger level for channels 1 ... 4

C0736 TRIGGER−SLOPE

0

0
1

LOW−HIGH edge
HIGH−LOW edge

OSZ
Selection of the trigger edge

C0737 TRIGGER DELAY

0.0

−100.0

{0.1 %}

999.9 OSZ

Setting of pretriggering and posttriggering

C0738 PROBE PERIOD

3

3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

1 ms
2 ms
5 ms
10 ms
20 ms
50 ms
100 ms
200 ms
500 ms
1 s
2 s
5 s
10 s
20 s
50 s
1 min
2 min
5 min
10 min

OSZ
Selection of the sampling period

C0739 NUMBER OF

CHANNELS

4

1

{1}

4 OSZ

Number of channels to be measured

C0740 DATA READ

0

OSZ

1

0

0

{1}

65535 Define the starting point for reading the data

memory. This enables a selective access to a
memory block

2

0

0
1

Inhibit "Read data"
Enable "Read data"

Inhibit "Read memory"

Advertising
This manual is related to the following products: