Configuration – Lenze EVS9332xS User Manual

Page 256

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−15

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0356

0

{1 ms}

65000 CAN

System bus time settings

1 CAN BOOT UP

3000

Required for CAN interconnection without
master

2 OUT2 CYCLE

0

0 = event−controlled process data transfer

3 OUT3 CYCLE

0

>0 = cyclic process data transfer

4 CAN DELAY

20

When the "Operational" NMT status is
reached (after "Pre−operational" or
"Stopped"), the ˜CANdelay˜ delay time is
started. After the delay time has elapsed, the
PDO´s CAN−OUT2 and CAN−OUT3 are
transmitted for the first time.

C0357

0

{1 ms}

65000 CAN

System bus monitoring times

l

After a fault message, the CAN objects
remain in receive position

1 CE1 MONIT

TIME

3000

CAN−IN1

2 CE2 MONIT

TIME

3000

CAN−IN2

3 CE3 MONIT

TIME

3000

CAN−IN3

C0358 RESET NODE

0

0
1

No function
CAN reset

CAN
Establish nodal reset pointfor system bus

C0359 CAN STATE

g 0

1
2
3

Operational
Pre−Operational
Warning
Bus off

CAN
System bus status

C0360

g 0

65535 CAN

Telegram counter (number of telegrams)
Count values > 65535: Restart with 0

1 MESSAGE OUT

All telegrams sent

2 MESSAGE IN

All telegrams received

3 MESSAGE

OUT1

Telegrams sent on CAN−OUT1

4 MESSAGE

OUT2

Telegrams sent on CAN−OUT2

5 MESSAGE

OUT3

Telegrams sent on CAN−OUT3

6 MESSAGE

OUT1

Telegrams sent via parameter channel 1

7 MESSAGE

OUT2

Telegrams sent on parameter channel 2

8 MESSAGE IN1

Telegrams received from CAN−IN1

9 MESSAGE IN2

Telegrams received from CAN−IN2

10 MESSAGE IN3

Telegrams received from CAN−IN3

11 MESSAGE IN1

Telegrams received from parameter
channel 1

12 MESSAGE IN2

Telegrams received via parameter channel 2