Configuration, Code table – Lenze EVS9332xS User Manual

Page 247

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−6

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0081

s

MOT POWER

à

0.01

{0.01 kW}

150.00 Rated motor power acc. to nameplate

à

Depending on C0086

l

Change of C0086 resets value to the
assigned Lenze setting

l

Change of C0081 sets C0086 = 0

C0084

s

MOT RS

à

0.00

{0.01

W}

150.00 Motor stator resistance

à

Depending on C0086

l

Change of C0086 resets value to the
assigned Lenze setting

C0085

s

MOT LS

à

0.00

{0.01 mH}

655.35 Motor leakage inductance

à

Depending on C0086

l

Change of C0086 resets value to the
assigned Lenze setting

C0086

s

MOT TYPE

à

See motor selection list Motor type selection

à

Depending on the controller used

l

Change of C0086 resets C0006, C0022,
C0070, C0071, C0075, C0076, C0081,
C0084, C0085, C0087, C0088, C0089,
C0090, C0091 to the assigned Lenze
setting

Controller

Lenze
setting

Motor type
assigned

Lenze motor type

EVS9321

110

MDSKS56−23−150

MDSKSXX056−23, f

r

: 150 Hz

EVS9322

111

MDSKS56−33−150

MDSKSXX056−33, f

r

: 150Hz

EVS9323

112

MDSKS71−13−150

MDSKSXX071−13, f

r

: 150 Hz

EVS9324

116

MDSKS71−33−150

MDSKSXX071−33, f

r

: 150Hz

EVS9325

15

MDFKA80−120

MDFKAXX080−22, f

r

: 120Hz

EVS9326

19

MDFKA90−120

MDFKAXX090−22, f

r

: 120Hz

EVS9327

23

MDFKA100−120

MDFKAXX100−22, f

r

: 120Hz

EVS9328

27

MDFKA112−120

MDFKAXX112−22, f

r

: 120Hz

EVS9329

225

30kW−ASM−50

EVS9330

227

45kW−ASM−50

EVS9331

228

55kW−ASM−50

EVS9332

229

75kW−ASM−50

C0087

s

MOT SPEED

à

300

{1 rpm}

16000 Rated motor speed

à

Depending on C0086

l

Change of C0086 resets value to the
assigned Lenze setting

C0088

s

MOT CURRENT

à

0.2

{0.1 A}

500.0 Rated motor current

à

Depending on C0086

l

Change of C0086 resets value to the
assigned Lenze setting

C0089

s

MOT
FREQUENCY

à

10

{1 Hz}

1000 Rated motor frequency

C0090

s

MOT VOLTAGE

à

50

{1 V}

500 Rated motor voltage

à

Depending on C0086

l

Change of C0086 resets value to the
assigned Lenze setting

C0091

s

MOT COS PHI

à

0.50

{0.01}

1.00 Motor cos

j

à

Depending on C0086

l

Change of C0086 resets value to the
assigned Lenze setting

C0093 DRIVE IDENT

g 0

1
93xx

Defective power section
No power section
93xx

Controller identification
93xx: type of servo inverter

Advertising
This manual is related to the following products: