Configuration

Code table

8

8.4

l

8.4−18

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0439

g −199.99

{0.01 %}

199.99 AOUT2

Display of analog input signals

1 (C0436)

2 (C0437)

3 (C0438)

C0440

s

STATE−BUS

1000

® Selection list 2 Configuration of state bus X5/ST

C0441 (C0440)

g

C0443 DIGIN−OUT

g 0

{1}

255 Signals at X5/E1 to X5/E5, decimal value

l

Binary interpretation indicates terminal
signals

C0444 (C0118)

g 0

1

C0450

s

NX

1000 FIXED0%

® Selection list 1 BRK1

Configuration of analog input signal

C0451

s

SET

1000 FIXED0

® Selection list 2 BRK1

Configuraton of digital input signal

C0452

s

SIGN

1000 FIXED0%

® Selection list 1 BRK1

Configuration of analog input signal

C0458

g −199.99

{0.01 %}

199.99 BRK1

Display of analog input signals

1 (C0450)

2 (C0452)

C0459 (C0451)

g

BRK1
Display of digital input signal

C0464 CUSTOMER I/F

g 0

1

original
changed

Customer interface
Status of selected basic configuration

l

Reassignment of terminals in a basic
configuration from C0005 does not
change C0005 and sets C0464 = 1.

l

Adding or removing of function blocks or
changing the signal flow among the
function blocks in a basic configuration of
C0005 sets C0005 = 0 and C0464= 1

Advertising