Table of attributes

8

8.6

l

8.6−1

EDSVS9332S EN 6.0−07/2013

8.6

Table of attributes

The attribute table describes the properties of the codes used. It enables you
to create your own communication programs for the controller.

How to read the table of attributes

Column

Abbreviation

Meaning

Code

Cxxxx

Name of the Lenze code

Index

dec

24575 − Lenze code
number

Index under which the
parameter is addressed
The subindex of array variables
corresponds to the Lenze
subcode number

Is only required for control via INTERBUS,
PROFIBUS DP or system bus (CAN)

hex

5FFFh − Lenze code
number

Data

DS

E

Data structure

Single variable
(only one parameter element)

A

Array variable
(several parameter elements)

DA

xx

Number of array elements
(subcodes)

DT

B8

Data type

1 byte bit−coded

B16

2 bytes bit−coded

B32

4 bytes bit−coded

FIX32

32−bit value with sign;
decimal with four decimal places

I32

4 bytes with sign

U32

4 bytes without sign

VS

ASCII string

Format

VD

LECOM format
(see also Operating Instructions
of the bus module)

ASCII decimal format

VH

ASCII hexadecimal format

VS

String format

VO

Octet string format for data blocks

DL

Data length in byte

The column "Important" contains further
information

Access

LCM−R/W Ra

Access authorisation for LECOM

Reading is always permitted

Wa

Writing is always permitted

W

Writing is restricted

Condition CINH

Condition for writing

Writing permitted only when controller is
inhibited