Configuration

Code table

8

8.4

l

8.4−24

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0578 TN FLD WEAK

50.0

2.0

{0.5 ms}

8192.0 Field weakening controller

Reset time Tn
C0578 = 8000 ms: Switched off

C0579 MONIT NERR

3

0
1
2
3

Trip
Message
Warning
Off

NEERmonitoring
Configuration of "system deviation between
actual speed value and speed setpoint"
monitoring

C0580 MONIT SD8

3

0
3

Trip
Off

SD8 monitoring
Configuration of "Encoder error at X8"
monitoring

C0581 MONIT EER

0

0
1
2
3

Trip
Message
Warning
Off

EEr monitoring
Configuration of "external fault" monitoring

C0582 MONIT OH4

2

2
3

Warning
Off

OH4monitoring
Configuration of heatsink temperature
monitoring

C0583 MONIT OH3

®

0
2
3

Trip
Warning
Off

OH3 monitoring
Configuration of "fixed motor temperature"
monitoring

à

Depending on C0086

C0584 MONIT OH7

®

2
3

Warning
Off

OH7monitoring
Configuration of "adjustable motor
temperature"monitoring

à

Depending on C0086

Temperature monitoring via resolver input

C0585 MONIT OH8

3

0
2
3

Trip
Warning
Off

OH8 monitoring
Configuration of "adjustable motor
temperature" monitoring
Temperature monitoring via PTC input

C0586 MONIT SD2

0

0
2
3

Trip
Warning
Off

SD2 monitoring
Configuration of resolver monitoring

C0587 MONIT SD3

3

0
2
3

Trip
Warning
Off

SD3 monitoring
Configuration of "encoder at X9" monitoring

C0588 MONIT

H10/H11

0

0

Trip

H10 / H11 monitoring

2
3

Warning
Off

Setting C0588 = 2 or C0588 = 3 only allowed
for Lenze service

C0589 MONIT P03

2

0
2
3

Trip
Warning
Off

P03monitoring
Configuration of following error monitoring

l

The following error is monitored by the
DFSET function block. The monitoring is
only active if DFSET is used.

C0590 MONIT P13

0

0
2
3

Trip
Warning
Off

P13 monitoring
Configuration of angle error monitoring

l

The following error is monitored by the
DFSET function block. The monitoring is
only active if DFSET is used.

C0591 MONIT CE1

3

0
2
3

Trip
Warning
Off

CE1 monitoring
Configuration of "CAN−IN1 fault" monitoring

C0592 MONIT CE2

3

0
2
3

Trip
Warning
Off

CE2monitoring
Configuration of "CAN−IN2 error" monitoring

C0593 MONIT CE3

3

0
2
3

Trip
Warning
Off

CE3 monitoring
Configuration of "CAN−IN3 error" monitoring