Configuration, Code table – Lenze EVS9332xS User Manual

Page 258

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−17

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0404

g −199.99

199.99 AIN1

Display of analog input signals

1 (C0402)

2 (C0403)

C0405 OUT

g −199.99

199.99 AIN2

Display of the output signal

C0407

s

AIN2−OFFSET

19503

FCODE−26/2

® Selection list 1 AIN2

Offset configuration

C0408

s

AIN2−GAIN

19505

FCODE−27/2

® Selection list 1 AIN2

Gain configuration

C0409

g −199.99

{0.01 %}

199.99 AIN2

Display of analog input signals

1 (C0407)

2 (C0408)

C0416

s

RESOLVER ADJ

0

0

{1}

99999999 Correction of resolver fault

For Lenze motors read out resolver errors
from nameplate

C0420

s

ENCODER
CONST

512

1

{1

inc/rev}

8192

l

Encoder constant for encoder input X8 in
increments per revolution

l

If an absolute value encoder is selected in
C0025, an SD7 trip is triggered when the
encoder constant is changed.

C0421

s

ENC VOLTAGE

5.00

5.00

{0.1 V}

8.00 Encoder voltage

Set size of voltage for encoder

l

PLEASE NOTE: incorrect entry can destroy
encoder

C0425 DFIN CONST

3

0
1
2
3
4
5
6

256 inc/rev
512 inc/rev
1024 inc/rev
2048 inc/rev
4096 inc/rev
8192 inc/rev
16384 inc/rev

DFIN
Number of Increments of the digital
frequency input

C0426 DFIN−OUT

g −32767

{1 rpm}

32767 Output signal of DFIN

C0427 DFIN

FUNCTION

0

0
1
2

2 phases
A pulse / B direction of rotation (right)
Pulse A or B

DFIN
Selection of the digital frequency signal

C0429 TP5 DELAY

0

−32767

{1 inc}

32767 DFSET, DFRFG

Dead time compensation for the touch probe
function

C0431

s

IN

5001 MCTRL−NACT

® Selection list 1 AOUT1

Configuration of analog input signal

C0432

s

OFFSET

19512 FCODE−109/1

® Selection list 1 AOUT1

Offset configuration

C0433

s

GAIN

19510 FCODE−108/1

® Selection list 1 AOUT1

Gain configuration

C0434

g −199.99

{0.01 %}

199.99 AOUT1

Display of analog input signals

1 (C0431)

2 (C0432)

3 (C0433)

C0436

s

IN

5002 MCTRL−MSET2

® Selection list 1 AOUT2

Configuration of analog input signal

C0437

s

OFFSET

19513 FCODE−109/2

® Selection list 1 AOUT2

Offset configuration

C0438

s

GAIN

19511 FCODE−108/2

® Selection list 1 AOUT2

Gain configuration

Advertising