Configuration, Code table – Lenze EVS9332xS User Manual

Page 263

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−22

EDSVS9332S EN 6.0−07/2013

IMPORTANT

Possible settings

Code

Selection

Lenze

Designation

No.

C0528

g −2

.

10

9

{1}

2

.

10

9

DFSET

1 0−PULSE A

Angular difference between 2 zero pulses

2 OFFSET

Offset results from C0523 × C0529 + C0252

3 PULSE DIST SET

Number of increments between two set
pulses at X5/E5.
Code is available from software version 6.2.

4 PULSE DIST ACT

Number of increments between two actual
pulses at X5/E4.
Code is available from software version 6.2.

C0529 MULTIP OFFSET

1

−20000

{1}

20000 Offset multiplier

C0530 DF

EVALUATION

0

0

With gearbox factor

DFSET
Evaluation of the digital frequency

1

Without gearbox factor

C0531 ACT 0 DIV

1

1

{1}

16384 DFSET actual zero pulse scaler

C0532 0−PULSE/TP

1

1
2
3

0−pulse
Touch probe
0 pulse and touch probe

DFSET zero pulse/touch probe
Selection of zero pulse, touch probe, or zero
pulse and touch probe

C0533 VP DENOM

1

1

{1}

32767 DFSET Vp denominator

Gain factor denominator

C0534 SYNC MODE

0

0
1
2
10
11
12
13

Inactive
Continuous
Continuously switchable
Once, fast way
Once, + direction
Once, − direction
Once, 2 × zero pulse

DFSET
Mode for synchronising the zero pulse and/or
touch probe

C0535 SET 0 DIV

1

1

{1}

16384 DFSET

Setpoint zero pulse divider

C0536

g −32767

{1}

32767 DFSET

Display of analog input signals

1 (C0521)

2 (C0522)

3 (C0523)

C0537 (C0524)

g −199.99

{0.01 %}

199.99 DFSET

Display of analog input signal

C0538

g

DFSET
Display of digital input signals

1 (C0525)

2 (C0526)

3 (C0527)

C0539 (C0520)

g −32767

{1 rpm}

32767 DFSET

Input signal display

C0540 FUNCTION

2

0
1
2
3
4
5

Analog input
Phase difference input
Resolver simulation + zero pulse
Resolver simulation without zero pulse
X10 = X9
X10 = X8

DFOUT
Function of the encoder outputs

C0541

s

AN−IN

5001 MCTRL−NACT

® Selection list 1 DFOUT

Configuration of analog input

C0542

s

DF−IN

1000 FIXEDPHI−0

® Selection list 4 DFOUT

Configuration of the dig. frequency input

C0544

s

SYN−RDY

1000 FIXED0

® Selection list 2 DFOUT

Synchronisation signal for the zero pulse

C0545 PH OFFSET

0

0

{1 inc}

65535 DFOUT

Angular offset

Advertising
This manual is related to the following products: