Installing of the standard device

Standard devices in the power range 15 ... 30 kW

Mounting in "cold plate" technique

4

4.2

4.2.4

l

4.2−5

EDSVS9332S EN 6.0−07/2013

d

b1

c

c1

a

a1

g

e

< 75 °C

L

b

9300std067

Fig. 4.2−3

Dimensions for mounting in "cold plate" technique 15 ... 22 kW

9300

Dimensions [mm]

Type

a

a1

b

b1

c

c1

d

e

1)

g

EVS9327−CS
EVS9328−CS

234

250

381

350

110

220

367

171

6.5

1)

For a fieldbus module plugged onto X1, consider mounting space for connecting cables

Apply heat conducting paste before screwing together the cooler and
cooling plate of the drive controller so that the heat transfer resistance is as
low as possible.

1. Clean the contact surface of cooler and cooling plate with spirit.

2. Apply a thin coat of heat conducting paste with a filling knife or brush.

– The heat conducting paste in the accessory kit is sufficient for an area

of approx. 1000 cm

2

.

3. Mount the drive controller on the cooler.

Dimensions

Mounting