Code table, Configuration – Lenze EVS9332xS User Manual

Page 242

Advertising
background image

Configuration

Code table

8

8.4

l

8.4−1

EDSVS9332S EN 6.0−07/2013

8.4

Code table

How to read the code table

Column

Abbreviation

Meaning

Code

Cxxxx

Code Cxxxx

l

Parameter value of the code can be defined
differently for each parameter set

l

Parameter value is accepted immediately (ONLINE)

1

Subcode 1 of Cxxxx

2

Subcode 2 of Cxxxx

v

Changed parameter of code or subcode is accepted after pressing

T V

s

Changed parameter of code or subcode is accepted after pressing

T V when

the controller is inhibited

Designation

Designation of the code

Lenze

Lenze setting (value at delivery or after restoring the delivery status with C0002)

à

The column "IMPORTANT" contains additional information

g

The code only displays a value. It cannot be configured.

Selection

1

{%}

99 Min. value

{unit}

max. value

IMPORTANT

Short, important explanation

Code

Possible settings

IMPORTANT

No.

Designation

Lenze Selection

C0002

s

PAR LOAD

0

Load parameter set

0

Default setting

Restore delivery status

1
2
3
4

Load parameter set 1
Load parameter set 2
Load parameter set 3
Load parameter set 4

Load and activate parameter set saved in the
controller

l

Parameter set 1 is loaded automatically
after every mains connection.

11
12
13
14

Load parameter set 1externally
Load parameter set 2 externally
Load parameter set 3 externally
Load parameter set 4externally

Load parameter set from the keypad in the
controllerand activate it

20

Load all parameter sets from the keypad in
the EEPROM of the controller.

l

The current parameter set in the RAM of
the controller is overwritten. Save the
parameter set.

C0003 PAR SAVE

0

Save parameter set

0

Executed

Saving completed

1
2
3
4

Save parameter set 1
Save parameter set 2
Save parameter set 3
Save parameter set 4

Save the parameters loaded in the controller
in the parameter set selected

11

Save all parameter sets into keypad

Copying parameter sets from the standard
device into the keypad XT

C0004 OP DISPLAY

56

0

{1}

1999 Status display

Keypad shows selected code in the operating
level if no other status messages from C0183
are active