Table B.C Dynamic Brake Modules

Drive Ratings

Catalog Number

(1)

(2)

(1)

The resistors listed in this tables are rated for 5% duty cycle.

(2)

Use of Rockwell resistors is always recommended. The resistors listed have been carefully
selected for optimizing performance in a variety of applications. Alternative resistors may be used,
however care must be taken when making a selection. Refer to the PowerFlex Dynamic Braking
Resistor Calculator
, publication PFLEX-AT001.

Input Voltage

kW

HP

Minimum
Resistance

Ω

120V 50/60 Hz
1-Phase

0.4

0.5

48

AK-R2-091P500

0.75

1.0

48

AK-R2-091P500

1.1

1.5

48

AK-R2-091P500

240V 50/60 Hz
1-Phase

0.4

0.5

48

AK-R2-091P500

0.75

1.0

48

AK-R2-091P500

1.5

2.0

48

AK-R2-091P500

2.2

3.0

32

AK-R2-047P500

240V 50/60 Hz
3-Phase

0.4

0.5

48

AK-R2-091P500

0.75

1.0

48

AK-R2-091P500

1.5

2.0

48

AK-R2-091P500

2.2

3.0

32

AK-R2-047P500

3.7

5.0

19

AK-R2-047P500

5.5

7.5

13

AK-R2-030P1K2

7.5

10.0

10

AK-R2-030P1K2

480V 50/60 Hz
3-Phase

0.4

0.5

97

AK-R2-360P500

0.75

1.0

97

AK-R2-360P500

1.5

2.0

97

AK-R2-360P500

2.2

3.0

97

AK-R2-120P1K2

4.0

5.0

77

AK-R2-120P1K2

5.5

7.5

55

AK-R2-120P1K2

7.5

10.0

39

AK-R2-120P1K2

11.0

15.0

24

AK-R2-120P1K2

(3)

(3)

Requires two resistors wired in parallel.

600V 50/60 Hz
3-Phase

0.75

1.0

120

AK-R2-360P500

1.5

2.0

120

AK-R2-360P500

2.2

3.0

82

AK-R2-120P1K2

4.0

5.0

82

AK-R2-120P1K2

5.5

7.5

51

AK-R2-120P1K2

7.5

10.0

51

AK-R2-120P1K2

11.0

15.0

51

AK-R2-120P1K2

(3)