A085, A086, A087 – Rockwell Automation 22B PowerFlex 40 FRN 1.xx - 6.xx User Manual

Page 73: Advanced program group, Continued)

Advertising
background image

Programming and Parameters

3-27

PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 6.xx User Manual

Publication 22B-UM001H-EN-E

Advanced Program Group

(continued)

A085 [Start Boost]

Related Parameter(s):

P031

,

P032

,

P034

,

P035

,

A084

,

A086

,

A087

,

A088

,

A125

Sets the boost voltage (% of

P031

[Motor NP Volts]) and redefines the Volts per Hz curve when A084

[Boost Select] = 0 “Custom V/Hz” and A125 [Torque Perf Mode] = 0 “V/Hz”.

Drive may add additional voltage unless Option 5 is selected.

Values

Default:

2.5%

Min/Max:

0.0/25.0%

Display:

0.1%

Frequency

Voltage

A087 [Break Frequency]

P032 [Motor NP Hertz]

P035 [Maximum Freq]

A085 [Start Boost]

P031 [Motor NP Volts]

A088 [Maximum Voltage]

A086 [Break Voltage]

A034 [Minimum Freq]

A086 [Break Voltage]

Related Parameter(s):

P031

,

P032

,

P034

,

P035

,

A084

,

A085

,

A087

,

A088

,

A125

Sets the frequency where break voltage is applied when A084 [Boost Select] = 0 “Custom V/Hz” and
A125 [Torque Perf Mode] = 0 “V/Hz”

Values

Default:

25.0%

Min/Max:

0.0/100.0%

Display:

0.1%

A087 [Break Frequency]

Related Parameter(s):

P031

,

P032

,

P034

,

P035

,

A084

,

A085

,

A086

,

A088

,

A125

Sets the frequency where break frequency is applied when A084 [Boost Select] = 0 “Custom V/Hz”
and A125 [Torque Perf Mode] = 0 “V/Hz”

Values

Default:

15.0 Hz

Min/Max:

0.0/400.0 Hz

Display:

0.1 Hz

22B-UM001.book Page 27 Wednesday, January 22, 2014 11:04 AM