1-20

Installation/Wiring

PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 6.xx User Manual
Publication 22B-UM001H-EN-E

2 Wire SNK Control -
Run FWD/Run REV

Internal Supply (SNK)

3 Wire SRC Control -
Non-Reversing

P036

[Start Source] = 1

A momentary input will
start the drive. A stop
input to I/O Terminal 01
will stop the drive as
specified by

P037

[Stop Mode].

Internal Supply (SRC)

External Supply (SRC)

3 Wire SNK Control -
Non-Reversing

Internal Supply (SNK)

3 Wire SRC Control -
Reversing

P036

[Start Source] = 1

A momentary input will
start the drive. A stop
input to I/O Terminal 01
will stop the drive as
specified by

P037

[Stop Mode]. I/O
Terminal 03
determines direction.

Internal Supply (SRC)

External Supply (SRC)

Input/Output

Connection Example

Stop-Run

Forward

Stop-Run

Reverse

01

02

03

04

11

01

02

Stop

Start

01

02

04

+24V

Common

Stop

Start

Each digital input draws 6 mA.

Stop

Start

01

02

03

04

11

01

02

03

Stop

Start

Direction

+24V

Common

Stop

Start

Direction

01

02

03

04

Each digital input draws 6 mA.