PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 6.xx User Manual

Publication 22B-UM001H-EN-E

Chapter

3

Programming and Parameters

Chapter 3 provides a complete listing and description of the PowerFlex
40 parameters. Parameters are programmed (viewed/edited) using the
integral keypad. As an alternative, programming can also be performed
using DriveExplorer™ or DriveExecutive™ software, a personal
computer and a serial converter module. Refer to

Appendix B

for catalog

numbers.

To configure a drive to operate in a specific way, drive parameters may
have to be set. Three types of parameters exist:

ENUM
ENUM parameters allow a selection from 2 or more items. Each item
is represented by a number.

Numeric Parameters
These parameters have a single numerical value (i.e. 0.1 Volts).

Bit Parameters
Bit parameters have four individual bits associated with features or
conditions. If the bit is 0, the feature is off or the condition is false. If
the bit is 1, the feature is on or the condition is true.

Some parameters are marked as follows.

For information on…

See page…

About Parameters

3-1

Parameter Organization

3-2

Basic Program Group

3-9

Advanced Program Group

3-14

Parameter Cross Reference – by Name

3-45

About Parameters

= Stop drive before changing this parameter.

= 32 bit parameter. Parameters marked 32 bit will have two

parameter numbers when using RS485 communications and
programming software.

32

22B-UM001.book Page 1 Wednesday, January 22, 2014 11:04 AM