background image

D-4

RJ45 DSI Splitter Cable

PowerFlex 40 Adjustable Frequency AC Drive FRN 1.xx - 6.xx User Manual
Publication 22B-UM001H-EN-E

Connecting Two Permanent Peripherals

Connecting an RS-485 Network

or

NEMA 1 Bezel

with DSI / MDI Hand Held

NEMA 4

Panel Mount Unit

Parameter 9 [Device Type] set to

"Master" and connected to Master

port (M) on RJ45 Splitter Cable

Parameter 9 [Device Type]

set to "Slave" and

connected to Slave port (S)

on RJ45 Splitter Cable

M

S

DSI / MDI Drive

or

AK-U0-RJ45-TR1

Terminating Resistor

(end of network)

DSI / MDI Drives

or

or

Customer supplied RJ45 male-to-RJ45 male
cables with wires connected at pins 4 and 5 only.

Both the Master (M) and Slave (S) ports on the RJ45 Splitter
Cable operate as standard RS-485 ports in this configuration.

AK-U0-RJ45-SC1

AK-U0-RJ45-TB2P

Two-position Terminal Block

22B-UM001.book Page 4 Wednesday, January 22, 2014 11:04 AM