Reading (03) and Writing (06) Drive Parameters
To access drive parameters, the Modbus register address equals the
parameter number. For example, a decimal “1” is used to address
Parameter d001 [Output Freq] and decimal “39” is used to address
Parameter P039 [Accel Time 1].
Additional Information
Refer to
http://www.ab.com/drives/
for additional information.