Block Transfer
Chapter 18
18-14
Keystrokes
Enter a bi-directional block transfer (like this example) by performing the
following steps.
Block Transfer 0 appears in the lower left corner of the screen, above the
processor’s current programming mode.
BLOCK
XFER
1
EN
BLOCK X FER READ
DATA ADDR:
MODULE ADDR:
BLOCK LENGTH:
FILE:
030
100
01
110- 110
DN
110
07
010
07
The Block Transfer enable bit is 01007; the done bit is 11007.
Note that the words BLOCK TRANSFER READ are flashing.
Insert the following values. The cursor will block automatically step
through the block transfer write instruction. The values are:
DATA ADDRESS
030
MODULE ADDRESS
142
BLOCK LENGTH
05
FILE
060Ć064
The write instruction should look like this:
EN
BLOCK X FER READ
DATA ADDR:
MODULE ADDR:
BLOCK LENGTH:
FILE:
042
30
05
070- 074
DN
113
07
013
07