Rockwell Automation 1772-L8_LW_LWP_LX_LXP,D17726.5.8 User Manual User Manual

Page 343

Advertising
background image

↑↑

DISPLAY

↑↑

Sequencer

Chapter 21

21-19

Cursor down one line.

The cursor is on the last digit of DATA of the third word in the command
buffer. The digits in step 3 for word 3 are intensified.

Continue adding your data:
003: 00001000 00100010
004: 00100000 00100010
005: 00000000 00100010
006: 00000010 00001010

To add data to WORD 2 press [Shift] [

] and cursor up or down

as needed.

Do not press [Cancel Command]. We will use the display to add a mask.

The word DISPLAY appears in the lower left corner of the Industrial
Terminal Screen.

BINARY DATA MONITOR

SEQUENCER OUTPUT

COUNTER ADDR: 200

STEP: 001

SEQUENCER LENGTH: 006

FILE: 600- 613

OUTPUT ADDR: 012

013

DATA: 00000000 00000000

00000000 00000000

MASK ADDR: 075

076

DATA: 00000000 00000000

00000000 00000000

STEP

WORD 1

WORD 2

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00001010

00000000 00001010

00001000 01000001

00000000 00010010

00000000 00100010

00000010 00001010

001

002

003

004

005

006

DATA: 00000000 00000000

000

The cursor is on the last digit OUTPUT ADDR(ess) of DATA in the
command buffer. The digits for OUTPUT ADDR 012, DATA
are intensified.

Cursor down one line.

The digits for MASK ADDR 075. DATA are intensified.

00101010 10101010

The screen does not change.

Advertising