Quick Reference

Appendix E

E-7

Important: The counter word address, XXX, is assigned to the counter
accumulated areas of the data table. To determine which addresses are
valid accumulated areas, the third digit from the right must be an
even number.

This Bit:

Contains This Information:

14

overflow/underflow bit

15

count complete bit

16

enable bit for CTD instruction

17

enable bit for CTU instruction

The word address displayed will be 3 or 4 digits long depending on the
data table size. When entering the word address, use a leading zero
if necessary.

Key

Symbol

Instruction

Name

1770ĆT3

Display

Rung Conditions

Status Bits

-(CTU)-

Up Counter

XXX

-(CTU)-

PR YYY

AC ZZZ

Each time the rung goes true, the

accumulated value is incremented one

counter. The counter continues counting

after the preset value is reached.

The accumulated value can be reset by

the CTR instruction

When the rung is true:

If AC> 999 bit 14 is set

When AC

PR bits 15 and 17 are set

When the rung is false:

Bit 14 and 15 are retained;

if they were set, bit 17 is reset

-(CTR)-

Counter Reset

XXX

-(CTR)-

PR YYY

AC ZZZ

XXX - Word address of the CTU

is resetting.

The preset and accumulated values are

automatically entered by the industrial

terminal. When the rung is true the CTU

and CTD accumulated value and status

bits are rest to 000.

When the rung is true:

Bits 14, 15, 16, 17 are reset

When the rung is false:

No action is taken

-(CTD)-

Down Counter

XXX

-(CTD)-

PR YYY

AC ZZZ

Each time the rung goes true, the

accumulated value is decreased by

one count.

When the rung is true:

AC is < 000

Bit 14 is set

When AC<PR bits 15 and 16 are set

When the rung is false:

Bits 14 and 15 are retained;

if they were set, bit 16 is reset

Counter Instructions