Program Editing
Chapter 24
24-10
Searching for the First Condition or Output Instruction in a Rung
When the processor is operating in the Remote Program mode, you can
access the first condition instruction of a rung from anywhere in the rung
by performing the following steps.
1.
Press [Search][
←
].
When the processor is not in the Program mode, the cursor moves off the
screen to the left. To bring it back on the screen:
2.
Press [
→
].
When the processor is operating in any mode, you can access the output
instruction by performing the following step.
1.
Press [Search][
→
].
Searching for a Single Rung
Single Rung Display
Upon power-up, a multiple rung display appears on the screen. You can
select the single rung format by performing the following steps.
1.
Press [Search][Display].
You can return to the multiple rung display.
2.
Press [Search][Display] again.
Searching for an Incomplete Rung
You can locate an incomplete rung caused by an interruption in
programming in any processor operating mode. Perform the
following step.
1.
Press [Shift][Search].