Sequencer

Chapter 21

21-13

BINARY DATA MONITOR

SEQUENCER OUTPUT

COUNTER ADDR: 200

STEP: 001

SEQUENCER LENGTH: 006

FILE: 400- 413

OUTPUT ADDR: 110

201

DATA: 00000000 00000000

00000000 00000000

MASK ADDR: 070

071

00000000 00000000

STEP

WORD 1

WORD 2

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000010 00000000

00000010 00000001

00000010 00010001

001

002

003

004

005

006

DATA: 00000010 01010001

00000010 00010001

00000010 01000001

00000010 00000000

SHIFT

To display your rung.

DATA: 00000010 01010001

CANCEL

COMMAND

The Sequencer Output instruction transfers the values of the current
sequencer step to a specified output word. Here are some characteristics of
the sequencer output instruction.

You can transfer up to 64 bits.

This instruction is programmed as an output instruction (can be

programmed in the same rung as a sequencer input instruction).

You can mask the unused output bits.

The counter is internally indexed by the instruction (external counter

instruction is not required).

The instruction requires 5-8 words of your program.

If the rung condition becomes:

True

The counter increments to the next step and transfers
the data.

False

No action is taken.

Sequencer Output