21ć20, Sequencer load – Rockwell Automation 1772-L8_LW_LWP_LX_LXP,D17726.5.8 User Manual User Manual

Page 344

Advertising
background image

Sequencers

Chapter 21

21-20

To display your rung.

BINARY DATA MONITOR

SEQUENCER OUTPUT

COUNTER ADDR: 200

STEP: 001

SEQUENCER LENGTH: 006

FILE: 600- 613

OUTPUT ADDR: 012

013

DATA: 00000000 00000000

00000000 00000000

MASK ADDR: 075

076

00000000 00000000

STEP

WORD 1

WORD 2

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00000000

00000000 00001010

00000000 00001010

00001000 01000001

00100000 00010010

00000000 00100010

00000010 00001010

001

002

003

004

005

006

DATA: 00101010 10101010

DATA: 00101010 10101010

INSERT

CANCEL

COMMAND

The Sequencer Load instruction places data into the sequencer file you
established in the data table for this instruction. Here are some
characteristics of the sequencer load instruction.

This instruction is programmed as an output instruction.

You cannot mask any unused bits.

The counter is internally indexed by the instruction (external counter is

not required).

This instruction requires 4-7 words of the user program memory.

A false-to-true rung transition enables the instruction.

When the rung becomes:

True

The instruction increments to the next step and loads the data.

False

No action is taken.

Use this instruction for:

Machine diagnostics – If the actual sequence of an operation becomes

mismatched with the desired sequence of operation as contained in the
sequencer input instruction, a fault signal can be enabled by the
user program.

Teach sequential operation – The I/O conditions representing the desired

operation can be loaded into the sequencer input tables as the machine is
manually stepped through the control cycle.

Sequencer Load