If the PROC indicator

And the processor

You should

Green

is in the Run mode operating normally

program is executing

outputs are enabled.

is in MEM STORE mode and EEPROM memory module is

being programmed. The indicator will be ON for a few seconds

and then then turn OFF.

No action required

Blinking Green

has an I/O configuration error

there is an illegal backplane switch combination (i.e., switch

4 is ON, switch 5 is OFF)

the I/O is not in complementary fashion (32Ćpt. I/O only).

Check the switch settings and

module placement.

Red

has a possible hardware failure

program is not executing

if switch 1 of the switch group assembly if OFF, outputs are

disabled

data lines on the I/O chassis could be shorted to ground

Cycle power.

If the problem still persists, call your

AĆB representative.

Off

is operating normally in Program or Remote Test mode
is operating in Run mode, it has a memory or program error

Change the processor to Program mode, correct

problem and cycle power.

If problem still persists, call your

AĆB representative.