Data Transfer File Instuction

Chapter 19

19-15

When the rung becomes:

True

The data of a word is transferred from File A to a designated
(output) word address.

False

No action is taken.

ATTENTION: The counter address for the Word-to-File Move
and the File-to-Word Move instructions should be used only for
the intended instruction and the corresponding instructions
which manipulate the accumulated value. Do not inadvertently
manipulate the preset or accumulated word. Changes to these
values could result in unexpected machine operation with
damage to equipment and/or injury to personnel.

Keystrokes
Enter a File-to-Word Move instruction by performing the following steps.

EN

FILE TO WORD MOVE

COUNTER ADDR:

POSITION:

FILE LENGTH:

FILE A:

WORD ADDR:

001

001

010

110- 110

030

030

15

First, enter a conditioned rung with a CTU instruction for 030.

CTU

030

PR 001

AC 001

12

FILE

The word FILE appears in the lower left corner of the industrial
terminal screen.