Intrinsic safety entity verification -6, Intrinsic safety entity verification – Rockwell Automation 1797-OE8H FLEX Ex HART Analog Modules User Manual User Manual

Page 104

Advertising
background image

Publication 1797-6.5.3 - March 2006

6-6 Apply FLEX Ex Analog I/O Modules

Intrinsic Safety Entity Verification

Next we must determine if the pressure to current analog transmitter and the
Flex Ex analog input module are compatible from an IS perspective. We will
make this determination for a IIC gas application.

The figure below shows an extraction of pertinent information from the
figures on page 6-3.

In the figure above, three key items are shown, the field device the
interconnecting cabling and the Flex Ex module (in this example, a
1797-IE8H). The entity verification is done for the gas group IIC. As the table
shows, the module’s entity parameters are compared to the combination of the
transmitter and the wiring entity parameters.

The module’s entity parameters are shown in the Module column on the left.
They must be compared with the parameters shown in the Total Loop column,
in the manner shown. The values in the Total Loop column are determined in
the following manner:

• Total Loop U

i

= Transmitter U

i

• Total Loop I

i

= Transmitter I

i

• Total Loop C

i

= (Transmitter C

i

+ Cabling C

i

per length) X (cable

length)

• Total Loop L

i

= (Transmitter L

i

+ Cabling L

i

per length) X (cable

length)

As long as the Module and Total Loop entity parameters satisfy the inequalities
shown the loop is acceptable for use in the hazardous environment.

=
=
=
=

=
=
=
=

Ci<10 pF/m

Li<0.5 uH/m

R<0.1

Ω/m

P/I transmitter

EEx ia IIC T4

Ui =3 0V

Ii = 165 mA

Ci = 22.5 nF

Li = 730 uH

+

Cable length = 10m

+

sig

10

1797-IE8H Analog Input

EEx ia/ib IIB/IIC T4

Uo<24.4V

lo<92.5 mA

275

23.7V

Ca = 119 nF

La = 4 mH

Module

Uo

Io

Ca

La

Module

Uo<24.4V

Io<92.5 mA

Ca=119 nF

La=4 mH

< or =
< or =
> or =
> or =

< or =
< or =
> or =
> or =

Total Loop

Ui

Ii

Ci

Li

Module

Ui=30V

Ii=165

Ci=22.6 nF

Li=735 uH

Distance

(length
(length

Distance

(10 m
(10 m

Cable

Ci per length)

La per length)

Cable

Ci=10 pF/m)

La=0.5 uH/m)

Total Loop

Ui

Ii

Ci

Li

Module

Ui=30V

Ii=165

Ci=22.5 nF

Li=735 uH

+

+
+

*
*

*
*