Set the 1769-sdn module’s node address, Set the 1769-sdn, Module’s node – Rockwell Automation 1769-L23E-QB1B_L23E-QBFC1B_L23-QBFC1B CompactLogix Packaged Controllers Quick Start and User Manual User Manual
Page 130: Address
Advertising
![background image](/manuals/581737/130/background.png)
130
Publication IASIMP-QS010B-EN-P - October 2009
Chapter 7 Optional - Configuration of the DeviceNet Network
Set the 1769-SDN Module’s Node Address
1. Launch RSNetWorx for DeviceNet software.
2. From the Tools menu, choose Node
Commissioning.
3. Click Browse.
4. Expand to the CompactLogix
Backplane and the 1769 Bus.
Depending on your system,
you might choose browse to
the 1769-SDN via the
EtherNet/IP network.
5. Expand the 1769-SDN and the
DeviceNet Port, and select the 1769-SDN.
6. Click OK.