2 card exchange updating of the data base, User defined data base – BendixKing KLN 89B - Pilots Guide User Manual

Page 34

Advertising
background image

tion or the computer, the KLN 89(B) will display Data Loader Not
Ready
. When the problem is corrected this prompt is removed
and the update operation can continue from where it left off.

If an internal test fails after the data has been loaded, the
KLN 89(B) will display Checksum Error, Data Base Invalid.
Press

F

to acknowledge. The KLN 89(B) will then display

Data Base Update Failed, Retry? Use the right outer knob to
position the cursor over the desired choice and press

F

.

There are other error messages that may be displayed. If you
have a problem that you can’t resolve, write down any error
messages to aid your Honeywell Service Center in identifying the
problem.

2.4.2 CARD EXCHANGE UPDATING OF THE DATA BASE

Having the front-loading data card makes KLN 89(B) very easy to
update the data base by exchanging cards.

Enclose the expired data base card in the mailer that the new card
was sent to you in. A return shipping label is included in the mailer.
Please affix this label to the outside of the mailer. Also, peel off the
protective backing from the adhesive on the end flap of the mailer.
Press the flap against the adhesive to seal the container.

Please return the expired card promptly by mailing immediately at
any mailbox. No postage is required if mailed from within the U.S.
Users will be billed for cards not returned and no additional cards will
be sent until either the expired card or payment for the expired card is
received.

2.5. USER DEFINED DATA BASE

In addition to the published data base of airports, VORs, NDBs, and
Intersections stored in the Jeppesen data base, you may create up to
500 other user-defined waypoints. Section 4.6, “Creating User-
defined waypoints” describes this further.

The KLN 89(B) contains an internal lithium battery that is used to
“keep-alive” the user-defined data base as well as flight plans. This
battery has a typical life of three to five years. It is highly recom-
mended that the battery be replaced every three years at an
authorized Honeywell Service Center.