Chapter 2 System Installation

1-77

1

2

Visual KV

Series

OK

OFF

ON

Scan time

OK

OFF

ON

Output of basic unit

OFF

ON

OFF

ON

800µs

800µs

Output of expansion unit

Receive

Communication cycle

in expansion unit

Receive

Receive

Input signal

Incomplete receive

Scan time

Receive

Communication cycle in

expansion unit

Receive

Input signal

Incomplete receive

2.2 Connecting Visual KV Series Expansion Units

2.2.4

Transferring I/O Information between Expansion Units
and the Basic Unit

An expansion unit operates at a cycle of 800 µs without depending on the scan time.
When performing input while setting the input time constant of an expansion unit to
10 µs, or when synchronizing the output of a basic unit with the output of an
expansion unit, pay strict attention to the following contents.

When inputting

When the scan time is longer than 800 µs (communication cycle) plus 10 µs

(input time constant)

Set the input signal ON time equal to or longer than the scan time.

When the scan time is equal to or shorter than 800 µs (communication

cycle) plus 10 µs (input time constant)
Set the input signal ON time to 810 µs or longer.

In the case of output

The output of an expansion unit is delayed by a maximum of 800 µs from the output
of a basic unit.

When synchronizing the output of an expansion unit with the output of a basic unit,
pay strict attention to the communication cycle.

Note: When the output ON time is 800 µs or shorter, the output may be aborted.

KVHKA Chap 02.p65

08.3.11, 11:11 AM

77