7.6 Display Interface Mode Programming

KV-300 Series Only

KV

-300

KV-10/80

Chapter 7 KV-L2 Serial Interface Module

1-290

7

Abort (XZ)

The abort command allows the KV-L2 to stop the current operation and accept a
new command. This command generates no response.

■ Abort command

Initialize

The command initializes all station nos. This command requires no station no., FCS,
and generates no response.

■ Initial command

Undefined command error response (IC)

This is a response returned when a command header code cannot be read or
undefined code was sent. Check the header code and send the correct code.

■ Response format

Error response when a command cannot be executed

This is an error response returned when a received command cannot be executed.
The error description is indicated in the end code.

■ Response format

Note 1: Header codes are specific to received commands.

Note 2: Some commands (combined commands) may have sub header code in
addition to the header code.

Station No.

nn

@

XZ

FCS

❋

C

R

Header

code

00 to 15

(in decimal)

Terminator

@

❋

❋

C

R

Station No.

nn

@

IC

FCS

❋

C

R

Header

code

00 to 15

(in decimal)

Terminator

Station No.

nn

@

FCS

❋

C

R

End code

nn

Header code
(sub-header code) of
received command

Terminator

KVHKA Chap 07_5to10.p65