KEYENCE Visual KV Series User Manual
Page 247
6.3 Functions
Chapter 6 Handheld Programmer
1-223
1
6
•
Any current value of the timer/counter which is not set on the program cannot be
changed.
•
Any current value of the timers cannot be changed in the PROGRAM mode.
•
TMH or TMS is specified using TMR. UDC is specified using CTR.
*1. In the case where the counter (C) input is ON and the up-down counter (UDC)
reset input is OFF:
*2. In the case contrary to the above *1:
Key operation
Basic operation
Example of operation (In the RUN mode)
When the TIMER/COUNTER CURRENT VALUE CHANGE function is accessed,
pressing
@
#, $
alternates between the decimal display and hexadecimal display.
CTH
ENT
R-SRCH
FNC
Timer (or counter) No.
ENT
R-SRCH
ENT
R-SRCH
Current value
OR
9
ORB
6
CTR
(C)
TMR
(T)
Key operation
Display
Description
RUN
Initial display (RUN mode)
LD 00000
T/C CURT-V #00010
Access TIMER/COUNTER CURRENT VALUE
TMR000
CHANGE [CHG: T/C CURT-V] function.
T/C CURT-V #00010
Specify CTR001. Then current value (10) is
CTR001 #00000
displayed.
T/C CURT-V #00010
Enter desired value as new current value.
CTR001 #00180
T/C CURT-V #00180
Current value has been changed.
CTR001
RUN
Return to initial display of RUN
mode.
FNC
ENT
R-SRCH
ORB
6
CLEAR
SET
1
RES
0
ENT
R-SRCH
SET
1
ENT
R-SRCH
CTR
(C)
AND
8
AND
8
KVHKA Chap 06_3&4&5.p65
08.3.11, 11:17 AM
223