6.3 Functions

Chapter 6 Handheld Programmer

1-223

1

6

•

Any current value of the timer/counter which is not set on the program cannot be
changed.

•

Any current value of the timers cannot be changed in the PROGRAM mode.

•

TMH or TMS is specified using TMR. UDC is specified using CTR.

*1. In the case where the counter (C) input is ON and the up-down counter (UDC)

reset input is OFF:

*2. In the case contrary to the above *1:

Key operation

Basic operation

Example of operation (In the RUN mode)

When the TIMER/COUNTER CURRENT VALUE CHANGE function is accessed,
pressing

@

#, $

alternates between the decimal display and hexadecimal display.

CTH

ENT
R-SRCH

FNC

Timer (or counter) No.

ENT
R-SRCH

ENT
R-SRCH

Current value

OR

9

ORB

6

CTR

(C)

TMR

(T)

Key operation

Display

Description

RUN

Initial display (RUN mode)

LD 00000

T/C CURT-V #00010

Access TIMER/COUNTER CURRENT VALUE

TMR000

CHANGE [CHG: T/C CURT-V] function.

T/C CURT-V #00010

Specify CTR001. Then current value (10) is

CTR001 #00000

displayed.

T/C CURT-V #00010

Enter desired value as new current value.

CTR001 #00180

T/C CURT-V #00180

Current value has been changed.

CTR001

RUN

Return to initial display of RUN
mode.

FNC

ENT

R-SRCH

ORB

6

CLEAR

SET

1

RES

0

ENT

R-SRCH

SET

1

ENT

R-SRCH

CTR

(C)

AND

8

AND

8

KVHKA Chap 06_3&4&5.p65

08.3.11, 11:17 AM

223