KEYENCE Visual KV Series User Manual

Page 249

Advertising
background image

6.3 Functions

Chapter 6 Handheld Programmer

1-225

1

6

When the KV is write-disabled, the preset value cannot be changed.

Any preset value of the timer/counter which is not set on the program cannot be
changed.

TMH or TMS is specified using TMR.UDC is specified using CTR.

The preset value in the source program is also changed.

*1. In the case where the counter (C) input is ON and the up-down counter (UDC)

reset input is OFF:

*2. In the case contrary to the above *1:

Key operation

Basic operation

Example of operation (In the PROGRAM mode)

When the TIMER/COUNTER SETTING CHANGE function is accessed, pressing

@

#, $

alternates between the decimal display and hexadecimal display.

CTC

ENT
R-SRCH

FNC

Timer (or counter) No.

ENT
R-SRCH

ENT
R-SRCH

Preset value

RES

0

LD

7

CTR

(C)

TMR

(T)

Key operation

Display

Description

RUN

Display arbitrary line.

LD 00000

T/C SET-V #00020

Access TIMER/COUNTER SETTING

TMR000

CHANGE [CHG: T/C SET-V] function.

T/C SET-V #00100

Specify CTR001. Then preset value of

CTR001 #00000

CTR001 is displayed.

T/C SET-V #00100

Enter desired value as new current

CTR001 #00200

value. (200)

T/C SET-V #00200

Preset value has been changed.

CTR001

00000

Return to initial display.

LD 00000

FNC

ENT

R-SRCH

CLEAR

SET

1

RES

0

ENT

R-SRCH

ENT

R-SRCH

RES

0

ANL

2

LD

7

CTR

(C)

AND

8

KVHKA Chap 06_3&4&5.p65

08.3.11, 11:17 AM

225