KEYENCE Visual KV Series User Manual

Page 249

Advertising
background image

6.3 Functions

Chapter 6 Handheld Programmer

1-225

1

6

•

When the KV is write-disabled, the preset value cannot be changed.

•

Any preset value of the timer/counter which is not set on the program cannot be
changed.

•

TMH or TMS is specified using TMR.UDC is specified using CTR.

•

The preset value in the source program is also changed.

*1. In the case where the counter (C) input is ON and the up-down counter (UDC)

reset input is OFF:

*2. In the case contrary to the above *1:

Key operation

Basic operation

Example of operation (In the PROGRAM mode)

When the TIMER/COUNTER SETTING CHANGE function is accessed, pressing

@

#, $

alternates between the decimal display and hexadecimal display.

CTC

ENT
R-SRCH

FNC

Timer (or counter) No.

ENT
R-SRCH

ENT
R-SRCH

Preset value

RES

0

LD

7

CTR

(C)

TMR

(T)

Key operation

Display

Description

RUN

Display arbitrary line.

LD 00000

T/C SET-V #00020

Access TIMER/COUNTER SETTING

TMR000

CHANGE [CHG: T/C SET-V] function.

T/C SET-V #00100

Specify CTR001. Then preset value of

CTR001 #00000

CTR001 is displayed.

T/C SET-V #00100

Enter desired value as new current

CTR001 #00200

value. (200)

T/C SET-V #00200

Preset value has been changed.

CTR001

00000

Return to initial display.

LD 00000

FNC

ENT

R-SRCH

CLEAR

SET

1

RES

0

ENT

R-SRCH

ENT

R-SRCH

RES

0

ANL

2

LD

7

CTR

(C)

AND

8

KVHKA Chap 06_3&4&5.p65

08.3.11, 11:17 AM

225