KEYENCE Visual KV Series User Manual

Page 239

Advertising
background image

6.2 Basic Operations

Chapter 6 Handheld Programmer

1-215

1

6

Operand code

ON/OFF status

LD, LDB, AND, ANB, OR, ORB,

ON/OFF status of operand(ON/OFF status of

OUT, OUB, SET, RES, KEEP, DIFU, operand "CTH" is not displayed.)(For "LDB", "ANB"
DIFD, STP, HSP, STG, JMP, INT

and "ORB", output is inverted.)

SFT

ON/OFF status of first operand

HKEY

ON when key entry is detected.

W-ON, W-OFF, W-UE, W-DE

ON/OFF status of latch relay (second operand)

TMR, TMH, TMS

ON/OFF status of specified timer

C, UDC

ON/OFF status of specified counter

CTC

ON/OFF status of specified high speed counter
comparator

Others

ON/OFF status is not monitored. (" " is displayed.)

Key operation

Display

Description

RUN

Initial display

00000

Access ON/OFF MONITOR

LD 00000

mode.Line 0 is displayed.

00001

Scroll to next line.

OUT 00500

00002 -

Scroll to next line.

END

0001

Scroll to previous line.

OUT 00500

RUN

Return to initial display.

OFF

MON

CARD

ON

CLEAR

MON

CARD

MON

CARD

OFF

ON/OFF MONITOR

The ON/OFF status of the relay contact corresponding to the operand on each line
of the program is displayed for monitoring.

In the ON/OFF MONITOR mode, "SEARCH" and "SCROLL" can be executed,
while "OVERWRITE", "INSERT" and "DELETE" cannot be executed.

The ON/OFF statuses of the operand displayed in the ON/OFF MONITOR mode
are as follows:

... ON, ... OFF

Operation example

The ON/OFF monitor is disabled when the KV PLC is read-disabled.

KVHKA Chap 06_1&2.p65

08.3.11, 11:16 AM

215

Advertising