A/D and D/A Conversion Tables

Refer to the following tables when creating programs that involve A/D or D/A
conversion.

Voltage Conversion Table

Voltage range: +10 to -10 V

+10

+9

.00

4000

3800

4020

3820

.10

4040

3840

.20

Voltage integer
Numerical value of voltage down to two digits past the decimal point
Digital data corresponding to voltage

+10

+9
+8
+7
+6
+5
+4
+3
+2
+1
+0

-0
-1
-2
-3
-4
-5
-6
-7
-8
-9

-10

.00

4000
3800
3600
3400
3200
3000
2800
2600
2400
2200
2000
2000
1800
1600
1400
1200
1000

800
600
400
200

0

.10

4020
3820
3620
3420
3220
3020
2820
2620
2420
2220
2020
1980
1780
1580
1380
1180

980
780
580
380
180

.20

4040
3840
3640
3440
3240
3040
2840
2640
2440
2240
2040
1960
1760
1560
1360
1160

960
760
560
360
160

.30

4060
3860
3660
3460
3260
3060
2860
2660
2460
2260
2060

1740
1540
1340
1140

940
740
540
340
140

.40

4080
3880
3680
3480
3280
3080
2880
2680
2480
2280
2080

1720
1520
1320
1120

920
720
520
320
120

.50

3900
3700
3500
3300
3100
2900
2700
2500
2300
2100

1700
1500
1300
1100

900
700
500
300
100

.60

3920
3720
3520
3320
3120
2920
2720
2520
2320
2120

1680
1480
1280
1080

880
680
480
280

80

.70

3940
3740
3540
3340
3140
2940
2740
2540
2340
2140

1660
1460
1260
1060

860
660
460
260

60

.80

3960
3760
3560
3360
3160
2960
2760
2560
2360
2160

1640
1440
1240
1040

840
640
440
240

40

.90

3980
3780
3580
3380
3180
2980
2780
2580
2380
2180

1940

1920

1900

1880

1860

1840

1820
1620
1420
1220
1020

820
620
420
220

20

Example

The digital data is 3820 (shaded section in the following table) when the voltage
is 9.1 V.

KVHKA Chap 09.p65

08.3.11, 11:20 AM

357

Advertising