6.2 Basic Operations

Chapter 6 Handheld Programmer

1-213

1

6

Description

The ON/OFF status/current value for one element (relay contact, timer, counter,
data memory, or channel) is displayed on one line on the display.

Up to 16 elements can be registered for monitoring. While scrolling up or down
using

ON

or

OFF

, the information for these elements can be successively

monitored.

Information for up to 2 elements can be displayed at the same time on the upper
and lower lines of the display.

To enter the monitoring element, the lower line is used.

The upper line can also be used for fixed display. In this case, the lower line
alone is scrolled.

Once the monitoring element is registered, it is stored even if the monitoring is
completed. The registered elements, however, are cleared when the power
supply is turned off, when ALL CLEAR or HANDHELD PROGRAMMER CLEAR
is executed, or when the program is transferred or received.

The registered element can be changed, by overwriting, inserting, or deleting.

Operation example

Monitoring element entered is automatically registered. (Up to 16 elements)

Displaying monitoring result

The ON and OFF statues of the contact are expressed by the following symbols:

... ON, ... OFF

To display the current value of the timer, counter, or data memory and ON/OFF
statuses of the channel, the following 4 types of display are selectable: decimal,
hexadecimal, ASCII, or binary display.

Key operation

Display

Description

RUN

MULTI MONITOR
00000

MULTI MONITOR
00500

00500
00000

00500
00011

00011
00000

00011
T005 00010

T005 00010
00000

T005 00010
DM0001 00125

DM0001 00125
00000

DM0001 00125
00500

RUN

Initial display

MON

CARD

MON

CARD

ANB

5

RES

0

RES

0

OFF

SET

1

ENT

R-SRCH

SET

1

OFF

TMR

(T)

ANB

5

ENT

R-SRCH

OFF

SET

1

ENT

R-SRCH

OFF

ANB

5

RES

0

RES

0

ENT

R-SRCH

CLEAR

END

DM

MPP

ch

Access MULTI-MONITOR mode.
Monitor-ing element can be
entered on lower line.

ON/OFF status of output relay No.
500 is monitored. (OFF)

Display next input line by scrolling
down.

ON/OFF status of input relay No.
0011 is monitored. (ON)

Display next input line by scrolling
down.

Display next input line by scrolling
down.

Display next input line by scrolling
down.

ON/OFF statuses of output relay
Nos. 500 through 515 are moni-
tored. (relay Nos. 501 503 and 504
are ON.)

Current value of data memory No.
1 is monitored. (125)

Current value and ON/OFF status
of timer 5 are monitored. (10 and
OFF)

ENT

R-SRCH

Return to initial display.

KVHKA Chap 06_1&2.p65

08.3.11, 11:16 AM

213

Advertising