Chapter 4 KV-D20 Operator Interface Panel

1-149

1

4

Visual KV

Series

Example of frequency counter

Operate the KV-D20 to use the frequency counter function of the KV basic unit. In
the numeric value change mode of the operator screen, set the number of pulses of
one encoder rotation to obtain the measurement cycle and rpm.

➮ Refer to "Changing numeric values individually" on page 1-141.

The customized switches are assigned to the following functions:

F1: Starts operation.
F2: Finishes operation.
F3: Frequency (Hz) measurement
F4: Rotation (rpm) measurement

The customized lamps are assigned to the following functions:

LED1: Illuminates during operation.
LED2: Illuminates during frequency (Hz) measurement.
LED3: Illuminates during rotation (rpm) measurement.
LED4: Not used

➮ Refer to "4.5.3. Frequency Counter Function" on page 3-231 for details.

Operator screen

Switch comment screen

Lamp comment screen

4.3 Examples of Ladder Programs

F1

F2

F3

F4

F3

F4

1

2

3

4

FREQUENCY COUNTER:Hz

MEASUREMENT CYCLE: 0ms
PULSE FOR 1 ROTATION:0PLS
FREQUENCY:

0Hz

FREQUENCY COUNTER:rpm

MEASUREMENT CYCLE: 0ms
PULSE FOR 1 ROTATION:0PLS
ROTATION:

0rpm

F1:START

F2:END

F3:UNIT CHANGE (Hz)

F4:UNIT CHANGE (rpm)

LED1:MEASURING

LED2:UNIT (Hz)

LED3:UNIT (rpm)

LED4:RLY 2507