7.5 KV Mode Programming

KV-300 Series Only

KV

-300

KV-10/80

Chapter 7 KV-L2 Serial Interface Module

1-255

1

7

7.5.2

Serial Communications Procedure

The KV-L2 can be connected to a personal computer to read the current values and
set values of the counters and timers or the data memory values into the PC from
the KV-300 CPU for checking or updating.

Command transmission procedure

Commands are transmitted from a personal computer to the KV-L2 as follows:

Break signal

Upon receiving a break signal, the KV-L2 initializes its own communications buffer
and baud rate. The break signal should be transmitted only once before communica-
tion is initiated. The break signal need not be transmitted once communication is
successful.
The break signal must have the waveform shown below.

Note: Transmit the break signal for the first communication with a personal com-
puter after the KV IncrediWare (DOS) has been activated through a KV-L2 or KV-
P3E.
If transmission of the break signal fails, turn OFF the KV-300 CPU power switch to
initialize the communications program. Then begin communicating with the personal
computer.

Command

Response

KV-300

CPU

KV-L2

PC

Initializes communications
program in the KV-300 CPU.

1

2

3

4

5

Transmits a break signal (100 ms or longer)

Transmits communication start command (CR)

Transmits a command

Receives a response

Transmits communication end command (CQ)

Starts communications with the
KV-300 CPU.

Transmits a command that
instructs the KV-300 CPU to
perform a required operation.

Checks a response to the
required operation.

Terminates communication
with the KV-300 CPU.

+V

-V

SD

100 ms min.

KVHKA Chap 07_5to10.p65

08.3.11, 11:18 AM