3 altera cyclone iv de2-115 with nios and mii, 1 configuration and resource consumption, 2 functionality – BECKHOFF EtherCAT IP Core for Altera FPGAs v3.0.10 User Manual

Page 66: Altera cyclone iv de2-115 with nios and mii, Configuration and resource consumption, Functionality

Advertising
background image

Example Designs

III-54

Slave Controller

– IP Core for Altera FPGAs

6.3

Altera Cyclone IV DE2-115 with NIOS and MII

6.3.1

Configuration and resource consumption

Table 15: Resource consumption NIOS example design DE2-115 MII

Configuration

Resources

EP4CE115

Physical layer

2x MII,
TX Shift, MIIM, Link state
and PHY configuration
through MI

Les

19,062

17 %

Internal Function

3x FMMU
4x SyncManager
1 KB RAM


Registers

9,039

8 %

Distributed clocks

32 bit,
2x Sync, 2x Latch

M9K

264

61 %

Feature details

AL Status Code register,
Extended Watchdog,
AL Event Mask register,
Watchdog counter, EPU
and PDI Error counter,
Lost Link Counter,
RUN_LED,
LED Test

PLLs

1

25 %

PDI

Avalon
32 bit

Multiplier
elements

0

0 %

6.3.2

Functionality

Configure ETHERNET0 and ETHERNET1 for MII mode by setting jumpers JP1 and JP2 to 2-3.

Master is connected to Port ETHERNET0 of DE2-115 (left side, next to VGA). Port ETHERNET1 (right
side) can be used to connect other EtherCAT slaves.

The NIOS demo application performs the following tasks:

Accept any EtherCAT Slave State request (copying AL Control to AL Status register)

Display EtherCAT IP Core version and slave state on LCD

RUN LED is LEDG8

Link/Activity LEDs are LEDG6 and LEDG7

LEDG0

– LEDG5 are showing a running light if the slave is in OPERATIONAL mode

Digital input data from the switches SW0-SW17 is available in the Process Data RAM
(0x1000:0x1003).

Digital input data from the push buttons KEY0-KEY3 is available in the Process Data RAM
(0x1004).

Digital output data from Digital Output register (0x1100:0x1103) is visualized with LEDR0-LEDR17

Digital output data from Digital Output register (0x1104:0x1107) is visualized with the 7-segment
LED displays

The NIOS demo application is not suitable for production, it cannot be certified. Use the EtherCAT
Slave Stack Code (SSC, available from the ETG) for products.