7 scaling (cycle 11, din/iso: g72), Effect – HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual
Page 274
![background image](/files/816360/content/doc274.png)
274
Cycles: Coordinate Transformations
1
1
.7 SCALING (Cy
c
le 1
1
, DIN/ISO: G72)
11.7 SCALING (Cycle 11, DIN/ISO:
G72)
Effect
The TNC can increase or reduce the size of contours within a program,
enabling you to program shrinkage and oversize allowances.
The SCALING FACTOR becomes effective as soon as it is defined in
the program. It is also effective in the Positioning with MDI mode of
operation. The active scaling factor is shown in the additional status
display.
The scaling factor has an effect on
the working plane, or on all three coordinate axes at the same time
(depending on MP 7410)
dimensions in cycles
the parallel axes U,V,W
Prerequisite
It is advisable to set the datum to an edge or a corner of the contour
before enlarging or reducing the contour.
Enlargement: SCL greater than 1 (up to 99.999 999)
Reduction: SCL less than 1 (down to 0.000 001)
Resetting
Program the SCALING FACTOR cycle once again with a scaling factor
of 1.
Z
Z
X
X
Y
Y
X
Y
60
40
X
Y
36
30
(27)
(22.5)