5
Finally, the TNC returns the rotary axes to the initial position and
saves the measured values and deviations in the following Q
parameters:
Parameter number
Meaning
Q141
Standard deviation measured in the A axis
(–1 if axis was not measured)
Q142
Standard deviation measured in the B axis
(–1 if axis was not measured)
Q143
Standard deviation measured in the C axis
(–1 if axis was not measured)
Q144
Optimized standard deviation in the A axis
(–1 if axis was not measured)
Q145
Optimized standard deviation in the B axis
(–1 if axis was not measured)
Q146
Optimized standard deviation in the C axis
(–1 if axis was not measured)