401

16.6 MEA

S

. CIR

C

LE OUTSIDE (Cy

c

le

422, DIN/ISO: G422)

U

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made. Input range:
-99999.9999 to 99999.9999

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF

U

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999, alternatively PREDEF

U

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternatively PREDEF

U

Maximum limit of size for stud

Q277: Maximum

permissible diameter for the stud. Input range: 0 to
99999.9999

U

Minimum limit of size for the stud

Q278: Minimum

permissible diameter for the stud. Input range: 0 to
99999.9999

U

Tolerance for center 1st axis

Q279: Permissible

position deviation in the reference axis of the working
plane. Input range: 0 to 99999.9999

U

Tolerance for center 2nd axis

Q280: Permissible

position deviation in the minor axis of the working
plane. Input range: 0 to 99999.9999

X

Z

Q261

Q260