HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 367

Advertising
background image

HEIDENHAIN iTNC 530

367

15.1

0

D

A

TUM CIR

C

LE CENTER (Cy

c

le

416, DIN/ISO: G416)

U

Datum number in table

Q305: Enter the number in the

datum or preset table in which the TNC is to save the
coordinates of the bolt-hole circle center. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is on the bolt hole center. Input
range: 0 to 2999

U

New datum for reference axis

Q331 (absolute):

Coordinate in the reference axis at which the TNC
should set the bolt-hole center. Default setting = 0.
Input range: -99999.9999 to 99999.9999

U

New datum for minor axis

Q332 (absolute):

Coordinate in the minor axis at which the TNC should
set the bolt-hole center. Default setting = 0. Input
range: -99999.9999 to 99999.9999

U

Measured-value transfer (0, 1)

Q303: Specify

whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 332).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).

Advertising