Cycle parameters – HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual

Page 461

Advertising
background image

HEIDENHAIN iTNC 530

461

1

8

.4 MEA

S

URE KINEMA

TICS (Cy

c

le

451, DIN/ISO: G451; option)

Cycle parameters

U

Mode (0=Check/1=Measure)

Q406: Specify whether

the TNC should check or optimize the active
kinematics:
0: Check the active machine kinematics. The TNC
measures the kinematics in the axes you have
defined, but it does not make any changes to it. The
TNC displays the results of measurement in a
measurement log
1: Optimize the active machine kinematics. The TNC
measures and optimizes the kinematics in the axes
you have defined.

U

Exact calibration sphere radius

Q407: Enter the

exact radius of the calibrating ball used. Input range:
0.0001 to 99.9999

U

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF

U

Retraction height

Q408 (absolute): Input range

0.0001 to 99999.9999

„

Input 0:
Do not move to any retraction height. The TNC
moves to the next measuring position in the axis to
be measured. Not allowed for Hirth axes! The TNC
moves to the first measuring position in the series
A, then B, then C.

„

Input >0:
Retraction height in the untilted workpiece
coordinate system to which the TNC positions
before a rotary axis positioning in the spindle axis.
Also, the TNC moves the touch probe in the
working plane to the datum. The probe monitoring
is not active in this mode. Define the positioning
velocity in parameter Q253.

U

Feed rate for pre-positioning

Q253: Traversing

speed of the tool during positioning in mm/min. Input
range: 0.0001 to 99999.9999; alternatively FMAX,
FAUTO

, PREDEF.

U

Reference angle

Q380 (absolute): Reference angle

(basic rotation) for measuring the measuring points in
the active workpiece coordinate system. Defining a
reference angle can considerably enlarge the
measuring range of an axis. Input range: 0 to
360.0000

Example: Calibration program

4 TOOL CALL “TASTER“ Z

5 TCH PROBE 450 SAVE KINEMATICS

Q410=0

;MODE

Q409=5

;MEMORY

6 TCH PROBE 451 MEASURE KINEMATICS

Q406=1

;MODE

Q407=12.5 ;SPHERE RADIUS

Q320=0

;SETUP CLEARANCE

Q408=0

;RETR. HEIGHT

Q253=750

;F PRE-POSITIONING

Q380=0

;REFERENCE ANGLE

Q411=-90

;START ANGLE A AXIS

Q412=+90

;END ANGLE A AXIS

Q413=0

;INCID. ANGLE A AXIS

Q414=0

;MEAS. POINTS A AXIS

Q415=-90

;START ANGLE B AXIS

Q416=+90

;END ANGLE B AXIS

Q417=0

;INCID. ANGLE B AXIS

Q418=2

;MEAS. POINTS B AXIS

Q419=-90

;START ANGLE C AXIS

Q420=+90

;END ANGLE C AXIS

Q421=0

;INCID. ANGLE C AXIS

Q422=2

;MEAS. POINTS C AXIS

Q423=4

;NO. OF MEAS. POINTS

Q432=1

;PRESET

Advertising